28 Jinis Human Papilloma Virus Berisiko Tinggi (Pengetikan 16/18) Asam Nukleat

Katrangan singkat:

Kit iki cocok kanggo deteksi kualitatif in vitro saka 28 jinis virus papiloma manungsa (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) asam nukleat ing urin lanang / wadon lan sel exfoliated serviks wadon.HPV 16/18 bisa diketik, jinis sing isih ora bisa diketik kanthi lengkap, nyedhiyakake sarana tambahan kanggo diagnosa lan perawatan infeksi HPV.


Detail Produk

Tag produk

jeneng produk

HWTS-CC006A-28 Jinis Human Papilloma Virus Berisiko Tinggi (Pengetikan 16/18) Kit Deteksi Asam Nukleat (PCR Fluoresensi)

Epidemiologi

Kanker serviks minangka salah sawijining tumor ganas sing paling umum ing saluran reproduksi wanita.Panaliten nuduhake manawa infeksi HPV sing terus-terusan lan macem-macem infeksi minangka salah sawijining panyebab utama kanker serviks.Saiki, perawatan efektif sing diakoni isih kurang kanggo kanker serviks sing disebabake dening HPV, mula panemuan awal lan pencegahan infeksi serviks sing disebabake dening HPV minangka kunci kanggo nyegah kanker serviks.Penting banget kanggo nggawe tes diagnostik etiologi sing prasaja, spesifik lan cepet kanggo diagnosa klinis lan perawatan kanker serviks.

Saluran

Campur Reaksi Saluran Jinis
PCR-Mix1 FAM 18
VIC(HEX) 16
ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Kontrol internal
PCR-Mix2 FAM 6, 11, 54, 83
VIC(HEX) 26, 44, 61, 81
ROX 40, 42, 43, 53, 73, 82
CY5 Kontrol internal

Parameter teknis

Lumbung Cairan: ≤-18 ℃
urip beting 12 sasi
Tipe Spesimen Serviks Swab, Vagina Swab, Urine
Ct ≤28
CV <5.0%
LoD 300 eksemplar / ml
Instrumen sing ditrapake Applied Biosystems 7500 Sistem PCR Real-Time
Applied Biosystems 7500 Fast Real-Time PCR Systems
QuantStudio®5 Sistem PCR Real-Time
Sistem PCR Real-Time SLAN-96P
LightCycler®480 Sistem PCR Real-Time
LineGene 9600 Plus Sistem Deteksi PCR Real-Time
MA-6000 Real-Time Kuantitatif Thermal Cycler
Sistem PCR BioRad CFX96 Real-Time
BioRad CFX Opus 96 Sistem PCR Real-Time

Alur Kerja

Reagen ekstraksi sing disaranake: Kit DNA/RNA Viral Macro & Micro-Test (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (sing bisa digunakake karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) dening Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Tambah 200μL saline normal kanggo resuspensi pelet ing langkah 2.1, banjur ekstraksi kudu ditindakake miturut kanggo pandhuan kanggo nggunakake reagen ekstraksi iki.Volume elusi sing disaranake yaiku 80μL.
Reagen ekstraksi sing disaranake: QIAamp DNA Mini Kit (51304) utawa Kolom DNA/RNA Viral Macro & Micro-Test (HWTS-3020-50).Tambah 200μL saline normal kanggo resuspend pelet ing langkah 2.1, lan banjur extraction kudu conducted miturut pandhuan kanggo nggunakake reagen extraction iki.Volume sampel sing diekstrak kabeh 200μL, lan volume elusi sing disaranake yaiku 100μL.


  • Sadurunge:
  • Sabanjure:

  • Tulis pesen sampeyan ing kene lan kirimake menyang kita