17 Jinis HPV (16/18/6/11/44 Ngetik)
Jeneng produk
HWTS-CC015 17 Jinis Human Papillomavirus (16/18/6/11/44 Typing) Kit Deteksi Asam Nukleat (PCR Fluoresensi)
Epidemiologi
Kanker serviks minangka salah sawijining tumor ganas sing paling umum ing saluran reproduksi wanita. Wis dituduhake manawa infeksi HPV sing terus-terusan lan pirang-pirang infeksi minangka salah sawijining panyebab utama kanker serviks. Saiki isih ana kekurangan perawatan efektif sing ditampa sacara umum kanggo kanker serviks sing disebabake dening HPV. Mulane, deteksi dini lan pencegahan infeksi serviks sing disebabake dening HPV minangka kunci kanggo nyegah kanker serviks. Nggawe tes diagnostik sing prasaja, spesifik, lan cepet kanggo patogen nduweni makna sing penting banget kanggo diagnosis klinis kanker serviks.
Saluran
| Campuran PCR1 | FAM | 18 |
| VIC/HEX | 16 | |
| ROX | 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 | |
| CY5 | Kontrol internal |
| PCR-Mix2 | FAM | 6 |
| VIC/HEX | 11 | |
| ROX | 44 | |
| CY5 | Kontrol internal |
Parameter Teknis
| Panyimpenan | -18℃ |
| Umur simpan | 12 sasi |
| Jinis Spesimen | Sampel urin, sampel swab serviks wanita, sampel swab vagina wanita |
| Ct | ≤28 |
| LoD | 300 Salinan/mL |
| Spesifisitas | Ora ana reaktivitas silang karo Ureaplasma urealyticum, Chlamydia trachomatis saluran reproduksi, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Mold, Gardnerella lan jinis HPV liyane sing ora kalebu ing kit. |
| Instrumen sing Ditrapake | Sistem PCR Wektu Nyata Biosistem Terapan 7500 Sistem PCR Wektu Nyata Cepet Biosistem Terapan 7500 QuantStudio®5 Sistem PCR Wektu Nyata Sistem PCR Wektu Nyata SLAN-96P LightCycler®480 Sistem PCR Wektu Nyata Sistem Deteksi PCR Wektu Nyata LineGene 9600 Plus Siklus Termal Kuantitatif Wektu Nyata MA-6000 Sistem PCR Wektu Nyata BioRad CFX96 Sistem PCR Wektu Nyata BioRad CFX Opus 96 |
Alur Kerja
Reagen ekstraksi sing disaranake: Kit DNA/RNA Viral Macro & Micro-Test (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (sing bisa digunakake karo Ekstraktor Asam Nukleat Otomatis Macro & Micro-Test (HWTS-3006C, HWTS-3006B)) saka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Tambah 200μL larutan garam normal kanggo nyusut maneh pelet ing langkah 2.1, banjur ekstraksi kudu ditindakake miturut pandhuan panggunaan reagen ekstraksi iki. Volume elusi sing disaranake yaiku 80μL.
Reagen ekstraksi sing disaranake: QIAamp DNA Mini Kit (51304) utawa Kolom DNA/RNA Viral Macro & Micro-Test (HWTS-3020-50). Tambahake 200μL larutan garam normal kanggo ngresuspensi pelet ing langkah 2.1, banjur ekstraksi kudu ditindakake miturut pandhuan panggunaan reagen ekstraksi iki. Volume sampel sing diekstrak kabeh 200μL, lan volume elusi sing disaranake yaiku 100μL.
Reagen ekstraksi sing disaranake: Reagen Pelepasan Sampel Makro & Mikro-Tes (HWTS-3005-8I, HWTS-3005-8J, HWTS-3005-8K, HWTS-3005-8L). Tambahake 200μL reagen pelepasan sampel kanggo nyusupke maneh pelet ing langkah 2.1, banjur ekstraksi kudu ditindakake miturut pandhuan panggunaan reagen ekstraksi iki.