SARS-CoV-2/influenza A/influenza B
jeneng produk
HWTS-RT148-SARS-CoV-2/influenza A /influenza B Kit Deteksi Gabungan Asam Nukleat (PCR Fluoresensi)
Saluran
Jeneng Saluran | PCR-Mix 1 | PCR-Mix 2 |
Saluran FAM | gen ORF1ab | IVA |
Saluran VIC/HEX | Kontrol internal | Kontrol internal |
Saluran CY5 | N gen | / |
Saluran ROX | E gene | IVB |
Parameter teknis
Lumbung | -18 ℃ |
urip beting | 12 sasi |
Tipe Spesimen | swab nasofaring dan swab oropharyngeal |
Target | SARS-CoV-2 telung target (gen Orf1ab, N lan E) / influenza A / influenza B |
Ct | ≤38 |
CV | ≤10,0% |
LoD | SARS-CoV-2: 300 Salinan/mL virus influenza A: 500 Salinan/mL virus influenza B: 500 Salinan/mL |
Kekhususan | a) Asil tes silang nuduhake manawa kit kasebut kompatibel karo coronavirus manungsa SARSr- CoV, MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, virus respiratory syncytial A lan B, virus parainfluenza 1, 2 lan 3, rhinovirusA, B lan C, adenovirus 1, 2, 3, 4, 5, 7 lan 55, metapneumovirus manungsa, enterovirus A, B, C lan D, virus paru sitoplasma manungsa, virus EB, virus campak Human cytomegalovirus, rotavirus, norovirus, virus mumps, virus varicella zoster, Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionella, pertussis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycobacterium tuberculosis, Aspergi glabratus, Candida glauces reaksi silang antarane Pneumocystis yersini lan Cryptococcus neoformans. b) Kemampuan anti interferensi: pilih musin (60mg/mL), 10% (V/V) getih manungsa, diphenylephrine (2mg/mL), hydroxymethylzoline (2mg/mL), sodium chloride (ngandung pengawet) (20mg/mL), beklometason (20mg/mL), deksametason (20mg/mL), flunison (20μg/mL), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), flutikason (2mg/mL), histamin hidroklorida (5mg/mL), α-Interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL). ), ritonavir (60mg/mL), mupirocin (20mg/mL), azitromisin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mL), levofloxacin (10μg/mL) lan tobramycin (0.6mg/mL) .Asil kasebut nuduhake yen zat sing ngganggu ing konsentrasi ing ndhuwur ora duwe respon interferensi marang asil deteksi patogen. |
Instrumen sing ditrapake | Applied Biosystems 7500 Sistem PCR Real-Time Applied Biosystems 7500 Fast Real-Time PCR Systems SLAN ®-96P Sistem PCR Real-Time QuantStudio™ 5 Sistem PCR Wektu Nyata LightCycler®480 Sistem PCR Real-Time LineGene 9600 Plus Sistem Deteksi PCR Real-Time MA-6000 Real-Time Kuantitatif Thermal Cycler Sistem PCR BioRad CFX96 Real-Time BioRad CFX Opus 96 Sistem PCR Real-Time |