SARS-CoV-2/influenza A/influenza B

Katrangan singkat:

Kit iki cocok kanggo deteksi in vitro kualitatif SARS-CoV-2, influenza A lan influenza B asam nukleat saka swab nasofaring lan sampel swab oropharyngeal sing saka wong sing dicurigai infeksi SARS-CoV-2, influenza A lan influenza. B. Uga bisa digunakake ing seng di tuduh radhang paru-paru lan seng di tuduh kasus kluster lan kanggo deteksi kualitatif lan ngenali SARS-CoV-2, influenza A lan influenza B asam nukleat ing swab nasopharyngeal lan swab oropharyngeal conto infèksi Coronavirus novel ing kahanan liyane.


Detail Produk

Tag produk

jeneng produk

HWTS-RT148-SARS-CoV-2/influenza A /influenza B Kit Deteksi Gabungan Asam Nukleat (PCR Fluoresensi)

Saluran

Jeneng Saluran PCR-Mix 1 PCR-Mix 2
Saluran FAM gen ORF1ab IVA
Saluran VIC/HEX Kontrol internal Kontrol internal
Saluran CY5 N gen /
Saluran ROX E gene IVB

Parameter teknis

Lumbung

-18 ℃

urip beting 12 sasi
Tipe Spesimen swab nasofaring dan swab oropharyngeal
Target SARS-CoV-2 telung target (gen Orf1ab, N lan E) / influenza A / influenza B
Ct ≤38
CV ≤10,0%
LoD SARS-CoV-2: 300 Salinan/mL

virus influenza A: 500 Salinan/mL

virus influenza B: 500 Salinan/mL

Kekhususan a) Asil tes silang nuduhake manawa kit kasebut kompatibel karo coronavirus manungsa SARSr- CoV, MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, virus respiratory syncytial A lan B, virus parainfluenza 1, 2 lan 3, rhinovirusA, B lan C, adenovirus 1, 2, 3, 4, 5, 7 lan 55, metapneumovirus manungsa, enterovirus A, B, C lan D, virus paru sitoplasma manungsa, virus EB, virus campak Human cytomegalovirus, rotavirus, norovirus, virus mumps, virus varicella zoster, Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionella, pertussis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycobacterium tuberculosis, Aspergi glabratus, Candida glauces reaksi silang antarane Pneumocystis yersini lan Cryptococcus neoformans.

b) Kemampuan anti interferensi: pilih musin (60mg/mL), 10% (V/V) getih manungsa, diphenylephrine (2mg/mL), hydroxymethylzoline (2mg/mL), sodium chloride (ngandung pengawet) (20mg/mL), beklometason (20mg/mL), deksametason (20mg/mL), flunison (20μg/mL), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), flutikason (2mg/mL), histamin hidroklorida (5mg/mL), α-Interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL). ), ritonavir (60mg/mL), mupirocin (20mg/mL), azitromisin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mL), levofloxacin (10μg/mL) lan tobramycin (0.6mg/mL) .Asil kasebut nuduhake yen zat sing ngganggu ing konsentrasi ing ndhuwur ora duwe respon interferensi marang asil deteksi patogen.

Instrumen sing ditrapake Applied Biosystems 7500 Sistem PCR Real-Time

Applied Biosystems 7500 Fast Real-Time PCR Systems

SLAN ®-96P Sistem PCR Real-Time

QuantStudio™ 5 Sistem PCR Wektu Nyata

LightCycler®480 Sistem PCR Real-Time

LineGene 9600 Plus Sistem Deteksi PCR Real-Time

MA-6000 Real-Time Kuantitatif Thermal Cycler

Sistem PCR BioRad CFX96 Real-Time

BioRad CFX Opus 96 Sistem PCR Real-Time

Solusi PCR Total

alur kerja

  • Sadurunge:
  • Sabanjure:

  • Tulis pesen sampeyan ing kene lan kirimake menyang kita