Mycobacterium Tuberculosis Isoniazid Resistance Mutation

Katrangan singkat:

Kit iki cocok kanggo deteksi kualitatif situs mutasi utama ing sampel sputum manungsa sing diklumpukake saka pasien positif Tubercle bacillus sing nyebabake resistensi mycobacterium tuberculosis isoniazid: wilayah promotor InhA -15C>T, -8T>A, -8T>C;Wilayah promotor AhpC -12C>T, -6G>A;mutasi homozigot kodon KatG 315 315G>A, 315G>C.


Detail Produk

Tag produk

jeneng produk

HWTS-RT137 Mycobacterium Tuberculosis Isoniazid Resistance Mutation Detection Kit (Kurva Leleh)

Epidemiologi

Mycobacterium tuberculosis, sakcepete minangka Tubercle bacillus (TB), yaiku bakteri patogen sing nyebabake tuberkulosis.Saiki, obat anti-tuberkulosis lini pertama sing umum digunakake kalebu isoniazid, rifampicin lan hexambutol, lan liya-liyane. Obat anti-tuberkulosis baris kapindho kalebu fluoroquinolones, amikacin lan kanamycin, lan liya-liyane. Obat-obatan anyar sing dikembangake yaiku linezolid, bedaquiline lan delamani, lsp. Nanging, amarga nggunakake obat anti-tuberkulosis sing ora bener lan karakteristik struktur tembok sel mycobacterium tuberculosis, mycobacterium tuberculosis ngembangake resistensi obat kanggo obat anti-tuberkulosis, sing ndadekake tantangan serius kanggo nyegah lan ngobati tuberkulosis.

Saluran

FAM asam nukleat MP
ROX

Kontrol internal

Parameter teknis

Lumbung

≤-18 ℃

urip beting 12 sasi
Tipe Spesimen sputum
CV ≤5%
LoD Watesan deteksi bakteri tahan isoniazid jinis liar yaiku 2x103 bakteri/mL, lan watesan deteksi bakteri mutan yaiku 2x103 bakteri/mL.
Kekhususan a.Ora ana reaksi silang ing genom manungsa, mycobacteria nontuberculous liyane lan patogen pneumonia sing dideteksi dening kit iki.b.Situs mutasi gen tahan obat liyane ing Mycobacterium tuberculosis jinis liar, kayata wilayah penentu resistensi saka gen rifampicin rpoB, dideteksi, lan asil tes ora nuduhake resistensi marang isoniazid, sing nuduhake ora ana reaksi silang.
Instrumen sing ditrapake Sistem PCR Real-Time SLAN-96PSistem PCR BioRad CFX96 Real-Time

LightCycler480® Sistem PCR Wektu Nyata

Alur Kerja

Yen nggunakake Kit DNA/RNA Umum Macro & Micro-Test (HWTS-3019) (sing bisa digunakake karo Ekstraktor Asam Nukleat Otomatis Macro & Micro-Test (HWTS-3006C, HWTS-3006B)) dening Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. kanggo ekstraksi, tambahake 200μL saka kontrol negatif lan sampel sputum diproses kanggo dites ing urutan, lan nambah 10μL saka kontrol internal kapisah menyang kontrol negatif, sampel sputum diproses kanggo dites, lan langkah-langkah sakteruse kudu strictly digawa metu miturut instruksi extraction.Volume sampel sing diekstraksi yaiku 200μL, lan volume elusi sing disaranake yaiku 100μL.


  • Sadurunge:
  • Sabanjure:

  • Tulis pesen sampeyan ing kene lan kirimake menyang kita