Asam Nukleat Malaria

Katrangan singkat:

Kit iki digunakake kanggo deteksi kualitatif in vitro asam nukleat Plasmodium ing sampel getih perifer pasien sing dicurigai infeksi Plasmodium.


Detail Produk

Tag produk

jeneng produk

HWTS-OT074-Plasmodium Nucleic Acid Detection Kit (Fluoresensi PCR)
HWTS-OT054-Plasmodium Nucleic Acid Detection Kit (Fluoresensi PCR)

Sertifikat

CE

Epidemiologi

Malaria (singkatane Mal) disebabake Plasmodium, yaiku organisme eukariotik sel tunggal, kalebu Plasmodium falciparum Welch, Plasmodium vivax Grassi & Feletti, Plasmodium malariae Laveran, lan Plasmodium ovale Stephens.Iki minangka penyakit parasit sing ditularake nyamuk lan getih sing mbebayani banget kanggo kesehatan manungsa.

Saka parasit sing nyebabake malaria ing manungsa, Plasmodium falciparum Welch minangka sing paling mateni.Periode inkubasi parasit malaria beda-beda, sing paling cendhak yaiku 12-30 dina, lan sing luwih suwe bisa nganti 1 taun.Sawise paroxysm malaria, gejala kayata hawa adhem lan mriyang bisa uga katon.Pasien bisa ngalami anemia lan splenomegali.Pasien sing serius bisa ngalami koma, anemia abot, gagal ginjal akut sing bisa nyebabake pati pasien.Malaria disebar ing saindenging jagad, utamane ing wilayah tropis lan subtropis kayata Afrika, Amerika Tengah, lan Amerika Kidul.

Saluran

FAM Plasmodium asam nukleat
VIC (HEX) Kontrol internal

Parameter teknis

Lumbung Cairan: ≤-18 ℃ Ing peteng;Lyophilized: ≤30 ℃ Ing peteng
urip beting 12 sasi
Tipe Spesimen Getih wutuh, bintik getih garing
Ct ≤38
CV ≤5.0%
LoD 5 eksemplar/μL
Repeatability Ndeteksi referensi pengulangan perusahaan lan ngitung koefisien variasi CV saka deteksi Plasmodium Ct lan asil≤ 5% (n=10).
Kekhususan Ora ana reaktivitas silang karo virus influenza A H1N1, virus influenza H3N2, virus influenza B, virus demam dengue, virus ensefalitis B, virus respiratory syncytial, meningococcus, virus parainfluenza, rhinovirus, disentri basiler beracun, staphylococcus aureus, escherichia coli, pneumonia utawa streptococcus. pneumoniae, salmonella typhi, lan rickettsia tsutsugamushi, lan asil tes kabeh negatif.
Instrumen sing ditrapake Bisa cocog karo instrumen PCR neon mainstream ing pasar.

Sistem PCR Real-Time SLAN-96P
Sistem PCR ABI 7500 Real-Time
ABI 7500 Sistem PCR Wektu Nyata Cepet
QuantStudio5 Sistem PCR Real-Time
LightCycler480 Sistem PCR Real-Time
LineGene 9600 Plus Sistem Deteksi PCR Real-Time
MA-6000 Real-Time Kuantitatif Thermal Cycler
Sistem PCR BioRad CFX96 Real-Time
BioRad CFX Opus 96 Sistem PCR Real-Time

Alur Kerja

80b930f07965dd2ae949c479e8493ab


  • Sadurunge:
  • Sabanjure:

  • Tulis pesen sampeyan ing kene lan kirimake menyang kita