Klebsiella Pneumoniae, Acinetobacter Baumannii and Pseudomonas Aeruginosa and Drug Resistance Genes (KPC, NDM, OXA48 and IMP) Multiplex
jeneng produk
HWTS-RT109 Klebsiella Pneumoniae, Acinetobacter Baumannii lan Pseudomonas Aeruginosa lan Gen Resistensi Obat (KPC, NDM, OXA48 lan IMP) Kit Deteksi Multipleks (Fluoresensi PCR)
Sertifikat
CE
Epidemiologi
Klebsiella pneumoniae minangka patogen oportunistik klinis umum lan salah sawijining bakteri patogen penting sing nyebabake infeksi nosokomial. Nalika daya tahan awak suda, bakteri mlebu ing paru-paru saka saluran pernapasan, nyebabake infeksi ing pirang-pirang bagian awak, lan panggunaan awal antibiotik minangka kunci kanggo ngobati [1]. Situs paling umum saka infèksi Acinetobacter baumannii yaiku paru-paru, sing dadi patogen penting kanggo pneumonia Hospital acquired pneumonia (HAP), utamané Ventilator related pneumonia (VAP). Asring diiringi infeksi bakteri lan jamur liyane, kanthi karakteristik tingkat morbiditas sing dhuwur lan tingkat kematian sing dhuwur.Pseudomonas aeruginosa minangka basil gram-negatif non-fermentatif sing paling umum ing praktik klinis, lan minangka patogen oportunistik penting kanggo infeksi sing dipikolehi rumah sakit, kanthi karakteristik kolonisasi sing gampang, variasi gampang lan multi-drug.
Parameter teknis
Panyimpenan | ≤-18 ℃ |
urip beting | 12 wulan |
Tipe Spesimen | Sputum |
Ct | ≤36 |
CV | ≤5,0% |
LoD | 1000 eksemplar/mL |
Kekhususan | a) Tes reaktivitas silang nuduhake manawa kit iki ora duwe reaksi silang karo patogen pernapasan liyane, kayata Streptococcus pneumoniae, Neisseria meningitidis, Staphylococcus aureus, Klebsiella oxytoca, Haemophilus influenzae, Acinetobacter jelly, Acinetobacter hemolytica, Legionella Escheudomia fluorescens, Candida albicans, Chlamydia pneumoniae, Respiratory Adenovirus, Enterococcus lan sampel sputum tanpa target, lsp. b) Kemampuan anti-interferensi: Pilih mucin, minocycline, gentamicin, clindamycin, imipenem, cefoperazone, meropenem, ciprofloxacin hydrochloride, levofloxacin, asam clavulanic, lan roxithromycin, lan liya-liyane kanggo tes interferensi, lan asil nuduhake yen zat interferensi Klebsi ing ndhuwur ora ndeteksi interferensi pneumonia. Acinetobacter baumannii, Pseudomonas aeruginosa lan gen resistensi carbapenem KPC, NDM, OXA48 lan IMP. |
Instrumen sing ditrapake | Applied Biosystems 7500 Sistem PCR Real-Time, Applied Biosystems 7500 Sistem PCR Wektu Nyata Cepet, QuantStudio®5 Sistem PCR Real-Time, LightCycler®480 Sistem PCR Real-Time, LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, teknologi Bioer), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), Sistem PCR BioRad CFX96 Real-Time, BioRad CFX Opus 96 Sistem PCR Real-Time. |
Alur Kerja
Kit DNA/RNA Umum Macro & Micro-Test (HWTS-3019) (sing bisa digunakake karo Ekstraktor Asam Nukleat Otomatis Macro & Micro-Test (HWTS-3006C, (HWTS-3006B)) dening Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. disaranake kanggo ekstraksi sampel miturut langkah-langkah sing disaranake miturut langkah-langkah Kit FU.