Enterovirus Universal, EV71 lan CoxA16
Jeneng produk
HWTS-EV026B-Enterovirus Universal, EV71 lan Kit Deteksi Asam Nukleat CoxA16 (Fluoresensi PCR)
HWTS-EV020Y/Z-Beku-kering Enterovirus Universal, EV71 lan CoxA16 Nucleic Acid Detection Kit (Fluoresensi PCR)
Sertifikat
CE/MDA (HWTS-EV026)
Epidemiologi
Hand-foot-mouth disease (HFMD) minangka penyakit infèksius akut sing umum ing bocah-bocah. Biasane ana ing bocah-bocah ing umur 5 taun, lan bisa nyebabake herpes ing tangan, sikil, tutuk lan bagean liyane, lan sawetara bocah cilik bisa nyebabake komplikasi kayata miokarditis, edema paru, meningoencephalitis aseptik, lan liya-liyane.
Saiki, 108 serotipe enterovirus wis ditemokake, sing dipérang dadi patang klompok: A, B, C lan D. Enterovirus sing nyebabake HFMD macem-macem, nanging enterovirus 71 (EV71) lan coxsackievirus A16 (CoxA16) sing paling umum lan saliyane HFMD, bisa nyebabake ensefalitis sistem saraf pusat sing serius, kayata meningitis, paralisis.
Saluran
FAM | Enterovirus |
VIC (HEX) | CoxA16 |
ROX | EV71 |
CY5 | Kontrol internal |
Parameter teknis
Panyimpenan | Cairan: ≤-18 ℃ Ing petengLyophilization: ≤30 ℃ |
urip beting | Cairan: 9 wulanLyophilization: 12 sasi |
Tipe Spesimen | Sampel swab tenggorokan, cairan Herpes |
Ct | ≤38 |
CV | ≤5.0% |
LoD | 500 eksemplar / ml |
Instrumen sing ditrapake | Bisa cocog karo instrumen PCR neon mainstream ing pasar.Sistem PCR ABI 7500 Real-Time ABI 7500 Sistem PCR Wektu Nyata Cepet Sistem PCR Real-Time SLAN-96P QuantStudio®5 Sistem PCR Real-Time LightCycler®480 Sistem PCR Wektu Nyata LineGene 9600 Plus Sistem Deteksi PCR Real-Time MA-6000 Real-Time Kuantitatif Thermal Cycler Sistem PCR BioRad CFX96 Real-Time BioRad CFX Opus 96 Sistem PCR Real-Time |
Solusi PCR Total
Reagen ekstraksi sing disaranake: Kit DNA/RNA Viral Macro & Micro-Test (HWTS-3017) (sing bisa digunakake karo Extractor Asam Nukleat Otomatis Macro & Micro-Test (HWTS-EQ011)) dening Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ekstraksi kudu ditindakake miturut instruksi manual. Volume sampel sing diekstrak yaiku 200μL, lan volume elusi sing disaranake yaiku 80μL.
Reagen ekstraksi sing disaranake: Reagen Pelepasan Sampel Macro & Tes Mikro (HWTS-3005-8). Ekstraksi kudu ditindakake miturut instruksi manual. Sampel ekstraksi yaiku swab orofaringeal utawa sampel cairan herpes saka pasien sing diklumpukake ing situs. Tambah swab sing diklumpukake langsung menyang Reagen Sample Release Macro & Micro-Test, vortex lan aduk kanthi becik, panggonan ing suhu kamar suwene 5 menit, copot banjur walik lan aduk kanthi becik kanggo entuk RNA saben sampel.
Reagen ekstraksi sing disaranake: QIAamp Viral RNA Mini Kit (52904) dening QIAGEN utawa Ekstraksi Asam Nukleat utawa Reagen Pemurnian (YDP315-R). Ekstraksi kudu ditindakake kanthi ketat miturut instruksi manual.