Antibodi RBD Spike SARS-CoV-2
jeneng produk
HWTS-RT055A-Enzyme-Linked Immunosorbent Assay kanggo ndeteksi SARS-CoV-2 Spike RBD Antibodi
Sertifikat
CE
Epidemiologi
Penyakit Coronavirus 2019 (COVID-19) yaiku radhang paru-paru sing disebabake dening infeksi karo coronavirus anyar sing diarani sindrom pernapasan akut parah coronavirus 2 (SARS-CoV-2).SARS-CoV-2 minangka galur ing virus beta-CoV partikel kapsul ing wangun bunder utawa elips kanthi diameter sekitar 60nm-140nm.COVID-19 minangka penyakit infèksi pernapasan akut, lan populasi umume rentan.Sumber infeksi COVID-19 sing saiki dikenal yaiku kasus COVID-19 lan pembawa SARS-CoV-2 tanpa gejala.Populasi sing disuntik dening vaksin SARS-CoV-2 bisa ngasilake antibodi RBD utawa antibodi S saka SARS-CoV-2 sing bisa dideteksi ing serum lan plasma, sing bisa dadi indikator kanggo ngevaluasi efisiensi vaksinasi vaksin SARS-CoV-2.
Parameter teknis
Lumbung | 2-8 ℃ |
urip beting | 12 sasi |
Tipe Spesimen | serum manungsa, plasma, conto karo antikoagulan EDTA, natrium heparin lan natrium sitrat |
CV | ≤15,0% |
LoD | Kit kasebut divalidasi dening referensi LOD pabrikan kanthi tingkat persetujuan 100%. |
Kekhususan | Zat campur tangan sing dhuwur ing spesimen ora mengaruhi kinerja kit kanggo ndeteksi antibodi RBD spike SARS-CoV-2.Zat interfering sing diuji kalebu hemoglobin (500mg/dL), bilirubin (20mg/dL), trigliserida (1500 mg/dL), antibodi heterofil (150U/mL), faktor reumatoid (100U/mL), 10%(v/v) getih manungsa, phenylephrine (2mg/mL), oxymetazoline (2mg/mL), natrium klorida (kalebu pengawet) (20mg/mL), beclomethasone (20mg/mL), deksametason (20mg/mL), flunisolide (20μg/mL), Triamcinolone (2mg/mL), budesonide (2mg/mL), Mometasone (2mg/mL), fluticasone (2mg/mL), Histamine Dihydrochloride (5mg/mL), ainterferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), Peramivir (1mg/mL) lopinavir (500mg/mL), ritonavir (1mg/mL), mupirocin (20mg/mL), azitromisin (1mg/mL), cefprozil ( 40μg/mL) lan meropenem (200mg/mL).Levofloxacin (10μg/mL), tobramycin (0,6mg/mL), EDTA (3mg/mL), Heparin Sodium (25U/mL), lan Sodium Citrate (12mg/mL) |
Instrumen sing ditrapake: | Pembaca microplate universal kanthi dawa gelombang 450nm / 630nm. |
Alur Kerja
Pilihan 1.
Reagen ekstraksi sing disaranake: Kit DNA/RNA Viral Makro & Uji Mikro (HWTS-3001, HWTS-3004-32, HWTS-3004-48) lan Ekstraktor Asam Nukleat Otomatis Makro & Mikro (HWTS-3006).
Pilihan 2.
Reagen ekstraksi sing disaranake: Ekstraksi Asam Nukleat utawa Reagen Pemurnian (YDP302) dening Tiangen Biotech(Beijing) Co.,Ltd.