Gen Resistensi Carbapenem (KPC/NDM/OXA 48/OXA 23/VIM/IMP)

Katrangan Cekak:

Kit iki digunakake kanggo deteksi kualitatif gen resistensi carbapenem ing sampel sputum manungsa, sampel swab rektal utawa koloni murni, kalebu KPC (Klebsiella pneumonia carbapenemase), NDM (New Delhi metallo-β-lactamase 1), OXA48 (oxacillinase 48), OXA23 (oxacillinase 23), VIM (Verona Imipenemase), lan IMP (Imipenemase).


Rincian Produk

Tag Produk

Jeneng produk

Kit Deteksi Gen Resistensi Carbapenem HWTS-OT045 (KPC/NDM/OXA 48/OXA 23/VIM/IMP) (PCR Fluoresensi)

Epidemiologi

Antibiotik karbapenem iku antibiotik β-laktam atipikal kanthi spektrum antibakteri paling amba lan aktivitas antibakteri paling kuat. Amarga stabilitase marang β-laktamase lan toksisitas sing kurang, iki dadi salah sawijining obat antibakteri sing paling penting kanggo perawatan infeksi bakteri sing parah. Karbapenem stabil banget marang β-laktamase spektrum lanjut sing dimediasi plasmid (ESBL), kromosom, lan sefalosporinase sing dimediasi plasmid (enzim AmpC).

Saluran

  Campuran PCR 1 Campuran PCR 2
FAM IMP VIM
VIC/HEX Kontrol Internal Kontrol Internal
CY5 NDM KPC
ROX

OXA48

OXA23

Parameter Teknis

Panyimpenan

≤-18℃

Umur simpan 12 sasi
Jinis Spesimen Sputum, koloni murni, swab rektum
Ct ≤36
CV ≤5.0%
LoD 103CFU/mL
Spesifisitas a) Kit iki ndeteksi referensi negatif perusahaan sing wis distandardisasi, lan asilé nyukupi syarat referensi sing cocog.

b) Asil saka uji reaktivitas silang nuduhake yen kit iki ora duwe reaksi silang karo patogen pernapasan liyane, kayata Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Streptococcus pneumoniae, Neisseria meningitidis, Staphylococcus aureus, Klebsiella oxytoca, Haemophilus influenzae, Acinetobacter junii, Acinetobacter haemolyticus, Legionella pneumophila, Escherichia coli, Pseudomonas fluorescens, Candida albicans, Chlamydia pneumoniae, Adenovirus pernapasan, Enterococcus, utawa sampel sing ngemot gen resisten obat liyane CTX, mecA, SME, SHV, TEM, lan liya-liyane.

c) Anti-gangguan: Mucin, Minocycline, Gentamicin, Clindamycin, Imipenem, Cefoperazone, Meropenem, Ciprofloxacin Hydrochloride, Levofloxacin, Clavulanat acid, Roxithromycin dipilih kanggo uji gangguan, lan asilé nuduhaké yèn zat pengganggu sing kasebut ing ndhuwur ora duwé reaksi pengganggu kanggo deteksi gen resistensi carbapenem KPC, NDM, OXA48, OXA23, VIM, lan IMP.

Instrumen sing Ditrapake Sistem PCR Wektu Nyata Biosistem Terapan 7500

Sistem PCR Wektu Nyata QuantStudio®5

Sistem PCR Wektu Nyata SLAN-96P (Hongshi Medical Technology Co., Ltd.)

Sistem PCR Wektu Nyata LightCycler®480

Sistem Deteksi PCR Wektu Nyata LineGene 9600 Plus (FQD-96AHangzhouTeknologi Bioer)

Siklus Termal Kuantitatif Wektu Nyata MA-6000 (Suzhou Molarray Co., Ltd.)

Sistem PCR Wektu Nyata BioRad CFX96

Sistem PCR Wektu Nyata BioRad CFX Opus 96

Alur Kerja

Pilihan 1.

Reagen ekstraksi sing disaranake: Kit DNA/RNA Umum Makro & Mikro-Tes (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (sing bisa digunakake karo Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) dening Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.. Tambahake 200μL larutan garam normal menyang endapan talus. Langkah-langkah sabanjure kudu ngetutake pandhuan kanggo ekstraksi, lan volume elusi sing disaranake yaiku100μL. (utawa 0μL.)

Pilihan 2.

Reagen ekstraksi sing disaranake: Reagen Ekstraksi utawa Pemurnian Asam Nukleat (YDP302) dening Tiangen Biotech (Beijing) Co., Ltd. Ekstraksi kudu diwiwiti kanthi ketat miturut langkah 2 saka pandhuan panggunaan (tambahake 200μL buffer GA menyang endapan talus, lan kocok nganti talus ngambang kabeh). Gunakake banyu bebas RNase/DNase kanggo elusi, lan volume elusi sing disaranake yaiku 100μL.

Pilihan 3.

Reagen ekstraksi sing disaranake: Reagen Pelepasan Sampel Makro & Mikro-Tes. Sampel sputum kudu dikumbah kanthi nambahake 1mL larutan garam normal menyang endapan talus sing wis diolah ing ndhuwur, disentrifugasi kanthi kecepatan 13000r/menit suwene 5 menit, lan supernatan dibuwang (simpen 10-20µL supernatan). Kanggo koloni murni lan swab rektal, tambahake 50μL reagen pelepasan sampel langsung menyang endapan talus sing wis diolah ing ndhuwur, lan langkah-langkah sabanjure kudu diekstrak miturut pandhuan panggunaan.


  • Sadurunge:
  • Sabanjure:

  • Tulis pesenmu ing kene lan kirim menyang kita